Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.469 kW
04/09/2026 09:16 (2143 days) Production Consumption NET Usage
Now 1.877 kW 0.408 kW -1.469 kW
Today 4.398 kWh (0.474 kW) 4.480 kWh (0.483 kW) 0.082 kWh (0.009 kW)
  - This Week 115.402 kWh (26.308 kWh/day) 61.112 kWh (13.932 kWh/day) -54.290 kWh (-12.376 kWh/day)
  - This Month 168.007 kWh (20.033 kWh/day) 122.171 kWh (14.567 kWh/day) -45.836 kWh (-5.465 kWh/day)
  - This Year 1.397 MWh (14.203 kWh/day) 1.688 MWh (17.152 kWh/day) 0.290 MWh (2.948 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 155.156 kWh (22.165 kWh/day) 101.383 kWh (14.483 kWh/day) -53.773 kWh (-7.682 kWh/day)
Last 30 Days (03/10/2026) 632.948 kWh (21.098 kWh/day) 449.571 kWh (14.986 kWh/day) -183.377 kWh (-6.113 kWh/day)
Last One Year 6.173 MWh (16.911 kWh/day) 7.832 MWh (21.457 kWh/day) 1.659 MWh (4.546 kWh/day)
Lifetime Since PTO 36.963 MWh (17.245 kW/day) 41.198 MWh (19.221 kW/day) 4.235 MWh (1.976 kW/day)
Lifetime Since Install 36.997 MWh 41.778 MWh 4.781 MWh
Voltage/Current 251.6 V / 7.5 A 251.6 V / 1.6 A 251.6 V / -5.8 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/11/2021 21:46 (9.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.987 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.234 0.792 1.075 7.612 0.000 kW
0.773 kWh
0.000 kW
4.639 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.227 0.749 1.009 7.102
03 - 202224****** IQ7+M [5] VCOP 0.000 0.240 0.793 1.080 7.574
04 - 202232****** IQ7+ [5] VCOP 0.000 0.238 0.789 1.038 7.284
05 - 202244****** IQ7+M [5] VCOP 0.000 0.232 0.770 1.072 7.510
06 - 202245****** IQ7+M [5] VCOP 0.000 0.222 0.746 1.047 7.297
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 0.814 1.256 8.646 0.000 kW
0.816 kWh
0.000 kW
4.078 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.277 0.700 1.121 7.590
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 0.877 1.427 9.577
10 - 202244****** IQ7+M [5] VCOP 0.000 0.272 0.868 1.395 9.356
11 - 202224****** IQ7+M [5] VCOP 0.000 0.277 0.820 1.311 8.943
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.128 0.555 0.500 4.087 0.000 kW
0.567 kWh
0.000 kW
2.269 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.140 0.570 0.568 4.416
14 - 202216****** IQ7+ [5] VCOP 0.000 0.146 0.577 0.572 4.429
15 - 202245****** IQ7+M [5] VCOP 0.000 0.141 0.568 0.560 4.353
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.55 V Current/Power -4.14 A (-0.218 kW)
Remain Capacity/Energy 321.0 Ah (16.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 53.5 % State Of Health 100.0 %
Run Time 3d 5h 32m to empty Report Date 2021-11-11 23:59
voltag, current for each battery pack voltage, current, and SOC

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.