Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.127 kW
05/23/2026 23:22 (2187 days) Production Consumption NET Usage
Now 0.000 kW 0.127 kW 0.127 kW
Today 4.807 kWh (0.206 kW) 6.898 kWh (0.295 kW) 2.091 kWh (0.089 kW)
  - This Week 160.179 kWh (22.967 kWh/day) 156.167 kWh (22.391 kWh/day) -4.012 kWh (-0.575 kWh/day)
  - This Month 561.995 kWh (24.462 kWh/day) 355.889 kWh (15.491 kWh/day) -206.106 kWh (-8.971 kWh/day)
  - This Year 2.515 MWh (17.591 kWh/day) 2.416 MWh (16.895 kWh/day) -0.099 MWh (-0.695 kWh/day)
Yesterday 29.595 kWh (1.233 kW) 5.105 kWh (0.213 kW) -24.490 kWh (-1.020 kW)
Last 7 Days 160.179 kWh (22.883 kWh/day) 156.542 kWh (22.363 kWh/day) -3.637 kWh (-0.520 kWh/day)
Last 30 Days (04/23/2026) 698.958 kWh (23.299 kWh/day) 420.536 kWh (14.018 kWh/day) -278.422 kWh (-9.281 kWh/day)
Last One Year 6.381 MWh (17.483 kWh/day) 7.782 MWh (21.320 kWh/day) 1.401 MWh (3.837 kWh/day)
Lifetime Since PTO 38.081 MWh (17.405 kW/day) 41.926 MWh (19.162 kW/day) 3.846 MWh (1.758 kW/day)
Lifetime Since Install 38.115 MWh 42.506 MWh 4.392 MWh
Voltage/Current 249.3 V / 0.0 A 249.1 V / 0.5 A 249.2 V / 0.5 A
Meter

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/30/2023 23:54 (14.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 33.674 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.305 2.193 1.995 7.998 0.000 kW
2.140 kWh
0.000 kW
12.840 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.303 2.128 1.911 7.637
03 - 202224****** IQ7+M [0] ---- 0.000 0.305 2.194 1.992 7.974
04 - 202232****** IQ7+ [0] ---- 0.000 0.304 2.193 2.009 7.991
05 - 202244****** IQ7+M [0] ---- 0.000 0.303 2.053 1.844 7.376
06 - 202245****** IQ7+M [0] ---- 0.000 0.303 2.078 1.871 7.508
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.305 2.103 1.885 7.520 0.000 kW
2.205 kWh
0.000 kW
11.025 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.304 2.209 2.010 7.948
09 - 202217****** IQ7+ [0] ---- 0.000 0.304 2.173 1.996 7.917
10 - 202244****** IQ7+M [0] ---- 0.000 0.305 2.259 2.036 8.041
11 - 202224****** IQ7+M [0] ---- 0.000 0.304 2.282 2.058 8.110
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.239 1.673 1.575 6.421 0.000 kW
1.731 kWh
0.000 kW
6.926 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.246 1.694 1.614 6.653
14 - 202216****** IQ7+ [0] ---- 0.000 0.250 1.785 1.680 6.982
15 - 202245****** IQ7+M [0] ---- 0.000 0.250 1.773 1.677 6.963
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
1.442 kWh
0.000 kW
2.883 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.237 2.883 2.513 22.773
Panel Layout Each Group Production

Battery History
Voltage 53.29 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 432.0 Ah (22.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 72.0 % State Of Health 100.0 %
Run Time 10d 0h 0m to empty Report Date 2023-03-30 23:58
voltag, current for each battery pack voltage, current, and SOC