| Date Offset [+30][+10][+05][+01][-01] |
|---|
| Exporting to grid by 5.515 kW | |||
|---|---|---|---|
| 05/22/2026 12:34 (2186 days) | Production | Consumption | NET Usage |
| Now | 4.190 kW | -1.325 kW | -5.515 kW |
| Today | 13.334 kWh (1.059 kW) | 3.698 kWh (0.294 kW) | -9.636 kWh (-0.766 kW) |
| - This Week | 139.111 kWh (25.180 kWh/day) | 147.862 kWh (26.764 kWh/day) | 8.751 kWh (1.584 kWh/day) |
| - This Month | 540.927 kWh (25.131 kWh/day) | 347.584 kWh (16.149 kWh/day) | -193.343 kWh (-8.983 kWh/day) |
| - This Year | 2.494 MWh (17.622 kWh/day) | 2.407 MWh (17.010 kWh/day) | -0.087 MWh (-0.612 kWh/day) |
| Yesterday | 8.982 kWh (0.374 kW) | 14.480 kWh (0.603 kW) | 5.498 kWh (0.229 kW) |
| Last 7 Days | 182.207 kWh (26.030 kWh/day) | 160.485 kWh (22.926 kWh/day) | -21.722 kWh (-3.103 kWh/day) |
| Last 30 Days (04/22/2026) | 711.950 kWh (23.732 kWh/day) | 422.440 kWh (14.081 kWh/day) | -289.510 kWh (-9.650 kWh/day) |
| Last One Year | 6.378 MWh (17.475 kWh/day) | 7.795 MWh (21.355 kWh/day) | 1.416 MWh (3.880 kWh/day) |
| Lifetime Since PTO | 38.060 MWh (17.406 kW/day) | 41.918 MWh (19.171 kW/day) | 3.858 MWh (1.765 kW/day) |
| Lifetime Since Install | 38.094 MWh | 42.498 MWh | 4.404 MWh |
| Voltage/Current | 252.1 V / 16.6 A | 252.1 V / -5.3 A | 252.1 V / -21.9 A |
|
|||
| Micro-inverters [pcu_num:5, pcu_level:16] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 05/22/2026 12:34 (7.0 hours) | Number of Devices | 17 set | |||||||
| Current Power | 4.283 kW (0.252 kW/panel) | Today Energy | 13.434 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.290 | 0.296 | 0.890 | 0.636 | 12.690 | 0.285 kW 0.835 kWh |
1.713 kW 5.010 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.277 | 0.296 | 0.830 | 0.600 | 11.846 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.288 | 0.295 | 0.848 | 0.633 | 12.233 | |||
| 04 - 202232****** | IQ7+ | [5] VCOP | 0.292 | 0.296 | 0.865 | 0.616 | 12.417 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.280 | 0.296 | 0.717 | 0.589 | 11.024 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.286 | 0.294 | 0.860 | 0.612 | 12.224 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.264 | 0.284 | 0.716 | 0.568 | 11.507 | 0.270 kW 0.735 kWh |
1.349 kW 3.677 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.274 | 0.292 | 0.744 | 0.576 | 11.450 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.270 | 0.290 | 0.737 | 0.576 | 11.529 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.267 | 0.288 | 0.734 | 0.578 | 11.687 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.274 | 0.292 | 0.745 | 0.578 | 11.881 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.265 | 0.294 | 1.056 | 0.596 | 12.156 | 0.270 kW 1.075 kWh |
1.080 kW 4.300 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.270 | 0.295 | 1.074 | 0.625 | 12.069 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.272 | 0.295 | 1.082 | 0.645 | 12.470 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.273 | 0.295 | 1.088 | 0.649 | 12.544 | |||
| wind | 16 - 202320****** | IQ7XS | [0] ---- | 0.000 | 0.000 | 0.000 | 0.000 | 36.136 | 0.070 kW 0.223 kWh |
0.141 kW 0.447 kWh |
| 17 - 122214****** | IQ7PD | [5] VCOP | 0.141 | 0.157 | 0.447 | 0.206 | 5.451 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 104.47 V (19.37 A) | Voltage Charge | 54.82 V | Current/Power | 35.06 A / 1.922 kW |
| Int/Ext Temp | 39.8 °C / 36.3 °C | Flags | 00/04/0D | Energy Today | 5.680 kWh @ 2026-05-22 12:35 |
|
|||||
| Battery History | |||
|---|---|---|---|
| Voltage | 54.45 V | Current/Power | 2.70 A (0.147 kW) |
| Remain Capacity/Energy | 516.6 Ah (26.4 kWh) | Full Capacity/Energy | 548.1 Ah (28.1 kWh) |
| State Of Charge | 94.3 % | State Of Health | 91.4 % |
| Run Time | 11h 40m to full | Report Date | 2026-05-22 12:34 |
|
|||
| Voltage | 54.44 V | Cell (MIN/MAX) | 3.378 V / 3.431 V (0.053 V) |
|---|---|---|---|
| Current/Power | 1.02 A (55 W) | Runtime | 10h 14m to full |
| Remain Capacity/Energy | 172.2 Ah (8.8 kWh) | Full Capacity/Energy | 182.7 Ah (9.4 kWh) |
| State Of Charge | 94.3 % | State Of Health | 91.3 % |
| Temperature | 21.5 °C | Cycle | 253 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2026-05-22 12:34 |
| Voltage | 54.46 V | Cell (MIN/MAX) | 3.402 V / 3.406 V (0.004 V) |
|---|---|---|---|
| Current/Power | 0.17 A (9 W) | Runtime | 2h 52m to full |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 22.0 °C | Cycle | 181 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2026-05-22 12:35 |
| Voltage | 54.47 V | Cell (MIN/MAX) | 3.403 V / 3.406 V (0.003 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 21.4 °C | Cycle | 185 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2026-05-22 12:35 |
| Voltage | 54.45 V | Cell (MIN/MAX) | 3.402 V / 3.404 V (0.002 V) |
|---|---|---|---|
| Current/Power | 0.30 A (16 W) | Runtime | 1h 37m to full |
| Remain Capacity/Energy | 99.0 Ah (5.1 kWh) | Full Capacity/Energy | 99.5 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.5 % |
| Temperature | 21.3 °C | Cycle | 187 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2026-05-22 12:35 |
| Voltage | 54.42 V | Cell (MIN/MAX) | 3.399 V / 3.403 V (0.004 V) |
|---|---|---|---|
| Current/Power | 0.00 A (0 W) | Runtime | Stand-by |
| Remain Capacity/Energy | 98.7 Ah (5.1 kWh) | Full Capacity/Energy | 99.2 Ah (5.1 kWh) |
| State Of Charge | 99.5 % | State Of Health | 99.2 % |
| Temperature | 21.9 °C | Cycle | 187 |
| MOSFET | CFET = ON, DFET = ON | Reported | 2026-05-22 12:35 |